<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>14101</ErrorNumber>
<ErrorFamily>Satellite</ErrorFamily>
<ErrorMessage>
SAT: LUE Analog testpoint exceeded allowed maximum
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The analog testpoint feature is normally disabled. If this feature has not been
explicitly enabled, this error indicates a firmware bug. Otherwise, the voltage
applied to the LUE analog testpoint has exceeded the value set by the "set sat
ltpmax" parameter. This parameter is normally set to its maximum value of 4095.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Record error message and call Creo Service.
</text></DescriptionText>
</OperatorAction>
<Cause>
Possible firmware bug.
</Cause>
<Cause>
LUE analog testpoint voltage has exceeded the value set by the "set sat ltpmax"
parameter
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:47 2008 PST
</Updated>
<Links>
</Links>
</Error>